Adrian Corston 11 months ago in UNIFYBroker/Aderant Expert updated by Beau Harrison (Senior Software Engineer) 11 months ago 3

After changing and saving the "Operation Timeout" parameter on the Aderant Expert agent UI the value is not saved.  In the extensibility file, the value "PT0S" is always written.

As a workaround I have edited the extensibility file instead.


Affected Versions:
Fixed by Version:

Thanks Beau, I will try this out when I next work on this customer.

I just tested and it worked a treat.  Thank you very much!